ANESTHESIA MACHINE

 

Application:
The Anesthesia machine makes a good performance in Intensive Care Units (ICU),
Operation room, Anesthesiology Department and other departments. From high to
low acuity, simple to complex cases, pediatric to geriatric patients, Anesthesia
Systems offer you the choices you need in ventilation, monitoring and technique.
what’s more, our expertise in anesthesia delivery and ventilation is based on rich 23-
year history of developing anesthesia solutions that meet your needs. Good
performance based on High Security, High Accuracy, High Stability and accurate
monitoring.
Trust Points
– Simplicity: easy to use, easy to move with 4 wheels.
– Choice: adapt the equipment to your patients and procedures freely
– Patient Centered Ventilation: Precision in an anesthesia ventilator, from
conventional ventilation to advanced modes, including 5 modes: IPPV; A/C;
PCV; SIMV; SIGH, MAUN.
– Designed and manufactured by Superstar Medical with over 23 years
experience in this area.
– Flexible configurations to suit your needs.
– International standard and advanced technology suitable for wide range use.
– Compact interface and touch screen give you better operating experience.
– Over 2,000 units installed in the world

Features:
– 10.4” TFT LCD touch screen displays the Ventilation parameters, Alarming
information and Waveform.
– Electronic flow meter, instantly know the fresh gas flow to your patient.
– Integration breathing circuit design, ensure easy operating and keep tidy.
– Multiple working modes such as volume control and pressure limit, adapt to
wide range patient.
– Vaporizer with temperature, flow compensation and self-lock function, keep
safety anytime.
– Multiple parameters monitoring interface, make every parameter clear, let
users know the patient conditions in all aspects;
– Real time pressure-time, flow-time loop graphics and high precision ETCO2,
O2 concentration detection function included.
– Vital sign monitor and Anesthetic gas monitor are optional.
Safety:
– Three level alarming system, visual and sound alarm information.
– Intelligent dual system controls ensure safe use in clinics.
– With lots of alarming, reminding and protection functions.
– Advanced power management control technology.
– With built-in back up power source, when outside power source goes off,
back-up power source starts to work.
Specifications
Ventilation modes IPPV; A/C; PCV; SIMV; SIGH; MAUN
Ventilator parameter ranges
– Flow meter :O2(0.1-10L/min)
– N2O : (0.1-10L/min)
– AIR : (0.1-10L/min)
– Rapid oxygen supply : 35L/min-75L/min
– Tidal volume(Vt) : 0, 20 mL ~ 1500 mL
– Frequence(Freq): 1bpm ~ 100 bpm
– I/E : 4:1~1:8
– PEEP : 0cmH2O ~ 30 cmH2O
– Pressure triggering sensitivity(PTr): -20 cmH2O ~ 0 cmH2O (Based on PEEP)
– Flow trigger sensitivity (FTr): 0.5 L/min ~ 30 L/min
– Pressure control (PC) : 5 cmH2O ~ 60 cmH2O
– SIGH : 0(off) 1/100 ~ 5/100
– Apnea Ventilation : OFF,5 s ~ 60 s
– Pressure Limit : 20 cmH2O ~ 100 cmH2O
Monitored Parameters
– Frequence (Freq): 0 /min ~ 100 /min
– Tidal volume(Vt) : 0 mL ~ 2000 mL
– MV : 0 L/min ~ 100 L/min
– Oxygen concentration : 15 % ~ 100 %
Alarm and protection

– The AC power failure alarm : Power failure or no connection
– Internal battery backup low voltage alarm : <11.3±0.3V
– No tidal volume : ≤ 5Ml within 6s
– High oxygen concentration alarm : 19%-100% & Low oxygen concentration
alarm : 18%-99%
– High Airway pressure alarm : 20cmH2O-100cmH2O & Low Airway pressure
alarm : 0cmH2O-20cmH2O
– High Minute Volume alarm : Adult(5L/min-20L/min) & Low Minute Volume
alarm : Paed(1L/min-15L/min 0-10L/min)
– Continuous Pressure alarm : (PEEP+1.5kPa) over 16s
– Suffocation warning : 5s-60s no spontaneous ventilation
– The maximum limited pressure : <12.5 kPa
– Fan error : Show on screen
– Oxygen deficit : Show on screen
Working conditions
– Gas source O2, N2O, AIR
– Pressure 280kPa-600kPa
– Voltage 100-240V
– Power frequency 50/60Hz
Vaporizer

Anesthesia gas Adjustable scope % (volume percentage)
Halothane 0 ~ 5
Enflurane 0 ~ 5
Isoflurane 0 ~ 5
Sevoflurane 0 ~ 8